Характеристики
Описание товара
EONE ET310A Digital Multimeters storage Oscilloscope Handheld DSO,DDS Function Signal Generator upgrade version of ET310
Conversion range, the conversion between the table and the oscilloscope!
ET310A sensitivity of up to 50mV; ET310A sampling rate of 80MHz, ET310A bandwidth 20MHz. Oscilloscope + million with a table, with rechargeable batteries.general characteristic
display
128 2; 128 dot matrix FSTN LCD
Observation area
62mmx 62mm
be in a poor light
White, brightness can be divided into three levels
input resistance
10M
Battery
Built in 1000mAh lithium polymer battery,
auto shut off
60 ~ 5 minutes or disable
Power shortage
Charging time
About 3~4 hours (depending on the time of battery use)
Use time
More than 4 hours (factory new battery standard)
memory capability
DMM data and DSO waveforms of the 100 records *
Use environment
0C~+40C;<75%RH
Storage condition
-10C~ +60C ; <90%RH
external dimensions
86 mm2;186 mm 2;32mm
weight
325g (no other accessories)
Operating height
0~2000m
The power adapter
6V/500mA; 110V~250V, switching power supply
Characteristic of digital storage oscilloscope
Analog bandwidth
DC 20MHz ~ D (50mV/div ~ 10V/div)
Maximum real time sampling rate
80Msps
vertical resolution
8 bits
Nonlinearity
1 bit
number of channels
1
bound modes
DC/AC/GND
input impedance
About 10M
graduation
Vertical 4.8, level 12.8
Vertical sensitivity range
50mV/div ~ 200V/div
Time base
31.25ns/div ~ 20s/div
Vertical amplitude accuracy
(5%+ 0.2div)
time base accuracy
(0.01% + 0.1div)
Automatic zero reference
In DC/dB measurement
scan pattern
Auto/normal/single
trigger level
12 div (step 0.1div)
Trigger slope selection
Rising edge / falling edge
Trigger position adjustment
6 div (step 0.1div)
Automatic setting
Automatically set the time base and vertical amplitude
Cursor measurement function
DV, DT, 1/dt (frequency)
Automatic measurement function
Vp-p, Vavg, RMS, dBm
Automatic measurement accuracy
(5%+ 0.2div)
record length
12.8div
* analog bandwidth to the 20MHz voltage when the bandwidth is attenuated to 3db.
* vertical attenuation for 1-2-5 range switching
Digital million with table features
All the range of uncertainty is expressed as: (a% reading + words). Correction period one year, due to the need to adjust, see the service section. The environmental conditions of the guarantee are: 23 C 5 C; < 75%RH. (mV range can only be used to manually switch)
function
range
resolution
uncertainty
direct voltage
400.0mV
0.1mV
(1.5%rdg + 10dgt)
4.000V
1mV
(1.0%rdg + 10dgt)
40.00V
10mV
400.0V
100mV
1000V
1V
(1.5%rdg + 10dgt)
alternating voltage
True effective value
400.0mV
0.1mV
50Hz~400Hz
(1.5%rdg + 10dgt)
400Hz~2kHz (2kHz above only for reference)
(2.0%rdg + 10dgt)
4.000V
1mV
40.00V
10mV
400.0V
100mV
750V
1V
(2.0%rdg + ) (50Hz~400Hz) (10dgt)
direct current
40.00/400.0mA
10¼A /100¼A
(1.2%rdg + 10dgt)
4.000/20.00A
1mA /10mA
alternating-current
True effective value
40.00/400.0mA
10¼A /100¼A
(1.5%rdg + 10dgt)
50Hz~2kHz (2kHz above only for reference)
4.000/20.00A
1mA /10mA
resistance
400.0
0.1
(1.2%rdg + 5dgt)
4.000k
1
40.00k
10
400.0k
100
4.000M
1k
40.00M
10k
(3.0%rdg + 10dgt)
Capacitance
51.20nF
1pF
(3.0%rdg + 10dgt)
512.0nF
10pF
5.120¼F
100pF
51.20¼F
1nF
100.0¼F
10nF
(5%rdg + 3dgt)
frequency
5.12Hz ~ 10MHz
0.1Hz ~ 10kHz
(1.0%rdg + 5dgt), (the signal amplitude is not less than 1Vp-p, V AC or RMS AC, A 20mA)
duty cycle
0.1~99.9% (AC 1Vp-p)
Diode test
Open circuit voltage of about 1.5 V, the maximum test current of about 1.5mA
On-off test
Judge resistance: about 30
Automatic range switching
Can be applied to the measurement function
Range overflow tips
O. L (Over load)
Meter measuring speed
2.5 times per second
Dynamic data window
After the main display to maintain the dynamic refresh the actual measurement data
DB (-80~+80dB) reference impedance
2, 3, 8, 16, 50, 75, 93, 110, 125, 135, 150, 300, 600, 900, 1000, 1200
Fuse specifications
5 20; &Phi 0.5A/250V; 10 38, 20A/500V
С этим вором не связывайтесь Все что о нем написано хорошее он писал сам Держитесь подальше Он далеко от вас... Читать отзыв полностью...
Мошенник. Не покупайте у него. Разводит на деньги.... Читать отзыв полностью...
Очень рекомендую товар этого продавца, я купил гобелен Тайный ужин, имитация жаккардового эффекта, очень-очень красивая, очень-очень хорошая цена, и цена... Читать отзыв полностью...
добрый день. В чем разница между этими катушками? 071N0051 и 071N0808 - Установлен был 071N0808... Читать отзыв полностью...
Продавец - полный отстой. Кому не жалко своего времени - обращайтесь. Продавец сначала тянул время с отправкой, затем очень долго... Читать отзыв полностью...
Жулик не вздумайте иметь с ним дело... Читать отзыв полностью...