Описание товара
M18 Ultrasonic Transducer 50~1000mm Range Adjustable 15~30V Working Voltage
0~10V Signal Output Customization Accepted
IMPORTANT NOTICE BEFORE YOU ORDER:
This link is for measuring water/air, range at 50~1000mm, output signal is 0~10V , working voltage is 15~30V, cable length is 2 meter, installation method is on the top of water tank.
If your ordering information differs, please contact us for a requote.
We can also customize below signal outputs, just let me know which output you would require ?
1 Analog output(4~20mA), this one need to add 20USD extra.
1 Analog output(0~10V, 0~5V)
1 Switch value output PNP, NC, NO
1 Switch value output NPN, NC, NO
2 Switch value output PNP, NC, NO
2 Switch value output NPN, NC,NO
1. OUTLINE DIMENSIONS (UNIT: mm)
2. CONNECTING METHOD
3. CHARACTERISTIC
4. PROGRAMMED ANALOG OUTPUT FUNCTION
5. ADJUSTING THE EVALUATION LIMITS
The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply voltage -U or +U to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1s. LEDs indicate whether the sensor has recognized the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught with -U, A2 with +U.
TEACH-IN rising ramp (A2 > A1)
- Position object at lower evaluation limit
- TEACH-IN lower limit A1 with - U
- Position object at upper evaluation limit
- TEACH-IN upper limit A2 with + U
TEACH-IN falling ramp (A1 > A2):
- Position object at lower evaluation limit
- TEACH-IN lower limit A2 with + U
- Position object at upper evaluation limit
- TEACH-IN upper limit A1 with – U
6. LED DISPLAYS
7. ORDERING GUIDE
When you order, pls kindly advise us the following parameters for the most suitable products.
1: What's your measuring object?
2: Measurement range?
3: Power supply?
4: Signal output?
5: Installation method(on the top of tank?) 6: Your real application is like?
8. PRODUCT RANGE
ca
Не прислали товар,вышли все сроки и обманули с возвратом денег.Аферисты,не связывайтесь с ними....... Читать отзыв полностью...
добрый день. В чем разница между этими катушками? 071N0051 и 071N0808 - Установлен был 071N0808... Читать отзыв полностью...
Продавец - полный отстой. Кому не жалко своего времени - обращайтесь. Продавец сначала тянул время с отправкой, затем очень долго... Читать отзыв полностью...
С этим вором не связывайтесь Все что о нем написано хорошее он писал сам Держитесь подальше Он далеко от вас... Читать отзыв полностью...
Магазин №910733027 не советую иметь дело с этим магазином. Чистое кидалово. На запросы не отвечает. Все блокирует... Читать отзыв полностью...
Мошенник. Не покупайте у него. Разводит на деньги.... Читать отзыв полностью...